In order to detect the aberration from a wide field of view(FOV) on the retina with adaptive optics, we present a multiple-object Shack-Hartmann wavefront sensor(MOSHWFS) design. The simulated results indicate that the wavefront from our MOSHWFS can be reconstructed for multiple objects, and the measurement error can be less than λ∕7 with an MOSHWFS with an FOV of 6.7°, for maximum eye aberration. The experimental result with two objects indicates that the measurement error can be less than λ∕14, with the root mean square of the reference wavefront as 0.798λ and 0.895λ, respectively.
Adaptive optics(AO) systems are widespread and considered as an essential part of any large aperture telescope for obtaining a high resolution imaging at present.To enlarge the imaging field of view(FOV),multi-laser guide stars(LGSs) are currently being investigated and used for the large aperture optical telescopes.LGS measurement is necessary and pivotal to obtain the cumulative phase distortion along a target in the multi-LGSs AO system.We propose a high precision phase reconstruction algorithm to estimate the phase for a target with an uncertain turbulence profile based on the interpolation.By comparing with the conventional average method,the proposed method reduces the root mean square(RMS) error from 130 nm to 85 nm with a 30% reduction for narrow FOV.We confirm that such phase reconstruction algorithm is validated for both narrow field AO and wide field AO.
Multi-conjugation adaptive optics(MCAOs) have been investigated and used in the large aperture optical telescopes for high-resolution imaging with large field of view(FOV).The atmospheric tomographic phase reconstruction and projection of three-dimensional turbulence volume onto wavefront correctors,such as deformable mirrors(DMs) or liquid crystal wavefront correctors(LCWCs),is a very important step in the data processing of an MCAO's controller.In this paper,a method according to the wavefront reconstruction performance of MCAO is presented to evaluate the optimized configuration of multi laser guide stars(LGSs) and the reasonable conjugation heights of LCWCs.Analytical formulations are derived for the different configurations and are used to generate optimized parameters for MCAO.Several examples are given to demonstrate our LGSs configuration optimization method.Compared with traditional methods,our method has minimum wavefront tomographic error,which will be helpful to get higher imaging resolution at large FOV in MCAO.
Even in the early stage,endocrine metabolism disease may lead to micro aneurysms in retinal capillaries whose diameters are less than 10 μm.However,the fundus cameras used in clinic diagnosis can only obtain images of vessels larger than 20 μm in diameter.The human retina is a thin and multiple layer tissue,and the layer of capillaries less than10 μm in diameter only exists in the inner nuclear layer.The layer thickness of capillaries less than 10 μm in diameter is about 40 μm and the distance range to rod&cone cell surface is tens of micrometers,which varies from person to person.Therefore,determining reasonable capillary layer(CL) position in different human eyes is very difficult.In this paper,we propose a method to determine the position of retinal CL based on the rod&cone cell layer.The public positions of CL are recognized with 15 subjects from 40 to 59 years old,and the imaging planes of CL are calculated by the effective focal length of the human eye.High resolution retinal capillary imaging results obtained from 17 subjects with a liquid crystal adaptive optics system(LCAOS) validate our method.All of the subjects' CLs have public positions from 127 μm to 147 μm from the rod&cone cell layer,which is influenced by the depth of focus.
In order to measure the rotation angle error of the worm and gear mechanisms in the atmospheric dispersion corrector( ADC),a novel measurement system based on the autocollimator is designed in this paper.Based on the position relations between the shaft and spot converged by rays of autocollimator,the rotation angle can be calculated quickly and conveniently using a brief algorithm. An optical wedge is introduced to the measurement system for suppressing the awful measuring error caused by the axial wobbly error. The measurement system can measure the shaft rotation angle at any rotation position,which is the novel usage of the two-dimensional autocollimator. Its optical layout is very simple. Only an optical wedge and two plane mirrors are needed besides the autocollimator. The measurement accuracy of the proposed method is less than±0.5 arcmin. In the measurement of two worms and gears mechanisms in ADC,the rotation angle error are±0.05° and ±0.07° respectively,which all satisfies the design demand( ±0.1°). The proposed measurement system can be also suits for some engineering fields.
Wenjie LiQuanquan MuShaoxin WangChengliang YangHaiping WangZhaoliang CaoLi Xuan