您的位置: 专家智库 > >

国家自然科学基金(30800246)

作品数:10 被引量:14H指数:3
相关作者:沈国峰陈亚珠陈晟朱梦媛苏志强更多>>
相关机构:上海交通大学更多>>
发文基金:国家自然科学基金上海市科委重大科技攻关项目国家教育部博士点基金更多>>
相关领域:医药卫生生物学理学一般工业技术更多>>

文献类型

  • 10篇中文期刊文章

领域

  • 8篇医药卫生
  • 1篇生物学
  • 1篇天文地球
  • 1篇一般工业技术
  • 1篇理学

主题

  • 4篇HIFU
  • 4篇超声
  • 2篇相控
  • 2篇聚焦超声
  • 2篇高强度聚焦超...
  • 2篇SPHERI...
  • 2篇ULTRAS...
  • 2篇FPGA
  • 2篇MRI引导
  • 1篇震源
  • 1篇震源深度
  • 1篇治疗超声
  • 1篇治疗仪
  • 1篇软件开发
  • 1篇探头
  • 1篇体外
  • 1篇体外实验
  • 1篇嵌入式
  • 1篇热疗
  • 1篇肿瘤

机构

  • 5篇上海交通大学

作者

  • 5篇沈国峰
  • 4篇陈亚珠
  • 3篇陈晟
  • 2篇魏博
  • 2篇苏志强
  • 2篇朱梦媛
  • 1篇张胜发
  • 1篇乔杉
  • 1篇吴昊
  • 1篇杨博
  • 1篇蔡鸿斌
  • 1篇吉翔
  • 1篇李德辉
  • 1篇刘文杰
  • 1篇马锐锋

传媒

  • 5篇中国医疗器械...
  • 4篇Journa...
  • 1篇Journa...

年份

  • 3篇2014
  • 3篇2013
  • 1篇2012
  • 1篇2011
  • 1篇2010
  • 1篇2009
10 条 记 录,以下是 1-10
排序方式:
A New Full Bridge High Intensity Focused Ultrasound Power System with Harmonic Cancellation
2014年
The feasibility of a new full bridge high intensity focused ultrasound(HIFU) amplifier system with harmonic cancellation is evaluated in this study. Harmonic cancellation technique is applied to these power amplifiers, which can eliminate the 3rd harmonic and all even harmonics. Since this technique requires two channels of phase signal to control one channel of power amplifier, the signal generator is required to double its output. The transducer array proposed in this study has 100 elements. So we choose an FPGA chip to generate 200 driving signals, and each channel has a phase resolution of 2ns, less than 1°. The phase signal from the FPGA meets the requirement of driving the power amplifiers. The output waveform of one channel of power amplifier(voltage across the transducer) is evaluated, and shows fewer harmonic components.
吴昊沈国峰苏志强陈亚珠
嵌入式超声肿瘤温热治疗仪的研制被引量:4
2013年
该文报告了一种超声肿瘤温热治疗仪。它采用合理规划嵌入式平台和系统部件的结构,实现小型化和便携化;通过PID反馈算法控制温度,对靶区进行安全、有效的加热控制。
杨博沈国峰陈晟苏志强朱梦媛
关键词:肿瘤热疗超声热疗嵌入式小型化
MRI引导的相控型HIFU系统框架设计与软件开发被引量:2
2013年
在现有P-HIFU系统基础上,结合MRI厂商提供的接口,设计了MRI引导的P-HIFU治疗系统的架构,并开发了相应的应用软件。经试验表明,该系统的软件能实现适形治疗的需要。
马锐锋沈国峰乔杉魏博陈晟陈亚珠
关键词:高强度聚焦超声MRI引导软件开发
MRI引导的超声治疗系统中的超声探头定位方法被引量:1
2013年
该文研究了一种治疗超声探头坐标系统在磁共振中的定标方法,该方法首先在超声探头边沿加工6个定位槽或附着于探头边沿并垂直于探头表面的定位圆柱体作为定位标记物,将6个定位标记物两端12个圆心作为定位标记点,通过计算所有定位标记点在磁共振中的空间三维坐标,得到治疗超声探头与磁共振三维坐标系统的换算关系。另外,利用定位标记点的冗余信息,可以减少超声探头的定位误差,提高定位精度。
魏博沈国峰陈晟朱梦媛苏志强陈亚珠
关键词:磁共振治疗超声超声探头
The Research on Infrared Image Denoising in Getting an Undistorted Sound Field Distribution
2014年
Exploring the distribution of focused ultrasound field attracts more and more investigators' attention.Making use of the heat property of focused ultrasound, we can measure the distribution of temperature to calculate the distribution of focused ultrasound field. During the exploration, we found that the temperature rise rate had a liner relation to sound intensity. So we conducted experiments and got the infrared images with noise. In order to obtain an accurate distribution of focused ultrasound field, it's necessary to find out a solution to get rid of the noise in infrared images. In traditional, we use hydrophone to explore the distribution of focused ultrasound field even in nonlinear area. So the result got by hydrophone was considered as standard. So the investigation was focused on the experimental validation of a filter which was the most suitable way for image process of infrared chart. So the ability of the filter should be that removing most noise and the distribution of temperature rise rate is unchanged. Six kinds of filters were used to deal with the raw data to obtain related information, from the results, we drew a conclusion that gauss filter was superior to the others filter, and a non- distortion distribution of focused ultrasound field would be get by the use of Gaussian filter.
苏志强沈国峰余瑛
关键词:INFRAREDFILTERGAUSSIAN
Real-Time MRI-Controlled Ultrasound Hyperthermia System for Superficial Tumor Treatment
2014年
Ultrasound hyperthermia is one of the most important methods in tumor treatment and characterized by non-invasiveness. Magnetic resonance imaging(MRI)-based temperature mapping techniques are safe compared with invasive methods and have been applied to detect temperature changes for a variety of applications. Among these techniques, the proton resonance frequency(PRF) method is relatively advanced. With a temperature measuring experiment, the effectiveness of PRF method has been proved, because the outcome temperature curve and the real temperature curve fit well. After that, an experiment has been conducted on tumors inside rabbit legs and the result indicates that this system is able to performance hyperthermia at targets based on PRF method in temperature mapping.
朱梦媛沈国峰苏志强陈晟吴昊
关键词:ULTRASOUNDHYPERTHERMIA
Multi-element Ultrasound Phased Array Applicator for the Ablation of Deep-seated Tissue被引量:4
2011年
High-intensity focused ultrasound (HIFU) has attracted increasing interests as a promising noninvasive modality for the treatment of deep tumors in the thoracic and abdominal cavity.A 90-element HIFU spherical phased array applicator operated at 1 MHz has been developed for deep tissue ablation.The spherical array with a 5 cm wide central hole has a 21 cm diameter and an 18 cm radius of curvature.Annular element distribution with unequal element spacing is used to reduce the number of elements.The array is constructed with piezoelectric lead zirconate titanate (PZT-8) circular elements that are 1.4 cm in diameter and have a wall with thickness of 0.2 cm.The array offers an effective ablating depth of at least 8 cm in the tissue for both simulations and ex vivo experiments.The simulations demonstrate that the developed array can steer the focus with good quality of intensity distributions up to 6 mm off center over ranges from 17 to 21 cm when the water depth is set at 11 cm.We also present the beam focusing capability in deep tissue through a series of ex vivo experiments by measuring discoloration areas after sonications.These results indicate that the developed array is ideal for the ablation of deep-seated tissue.
吉翔沈国峰白景峰李德辉余瑛乔杉陈亚珠
相控型HIFU系统软件的开发与应用被引量:1
2010年
介绍采用计算机图形学和数据库的相关技术,在自主研发的多阵元相控聚焦超声治疗设备上开发了一套可视化HIFU系统软件。经实验验证,该系统软件能够有效制定治疗规划,实施实验治疗方案,促进临床实验研究。
张胜发沈国峰吉翔李德辉蔡鸿斌陈亚珠
关键词:相控HIFU
High-intensity focused ultrasound with large scale spherical phased array for the ablation of deep tumors被引量:4
2009年
Under some circumstances surgical resection is feasible in a low percentage for the treatment of deep tumors. Nev-ertheless, high-intensity focused ultrasound (HIFU) is beginning to offer a potential noninvasive alternative to conventional therapies for the treatment of deep tumors. In our previous study, a large scale spherical HIFU-phased array was developed to ablate deep tumors. In the current study, taking into account the required focal depth and maximum acoustic power output, 90 identical circular PZT-8 elements (diameter=1.4 cm and frequency=1 MHz) were mounted on a spherical shell with a radius of curvature of 18 cm and a diameter of 21 cm. With the developed array, computer simulations and ex vivo experiments were carried out. The simulation results theoretically demonstrate the ability of the array to focus and steer in the specified volume (a 2 cm×2 cm×3 cm volume) at the focal depth of 15 to 18 cm. Ex vivo experiment results also verify the capability of the developed array to ablate deep target tissue by either moving single focal point or generating multiple foci simultaneously.
Xiang JIJing-feng BAIGuo-feng SHENYa-zhu CHEN
关键词:高强度聚焦超声震源深度体外实验
基于FPGA技术的P-HIFU系统相控信号发生器的研制被引量:1
2012年
研制的相控信号发生器,基于FPGA设计,能够满足相控超声聚焦,输出路数以及对相位分辨率的要求。经过实验测定,此相控信号发生器能输出256路相位信号,每路相位信号的相位分辨率为2nS,具有实现简单,系统可靠性较高等优点。
刘文杰沈国峰吴昊陈亚珠
关键词:相控HIFUFPGA